Publications


Vetrad Labでは、放射線防護、職業被ばく、線量評価、放射線安全教育、獣医療放射線安全に関する研究成果を国内外で発表しています。

Original Articles

  1. Usami K, Sakaguchi K, Otsuka M, Nagamoto K, Inoue R, Fukuda M, Yoshida K, Hosono M.
    ガラスバッジを用いた単純X線撮影における患者被ばく線量の測定.
    日本放射線技術學會雜誌. 2011;67(7):785–792.
  2. Morota K, Moritake T, Nagamoto K, Matsuzaki S, Nakagami K, Sun L, Kunugita N.
    Optimization of the Maximum Skin Dose Measurement Technique Using Digital Imaging and Communication in Medicine—Radiation Dose Structured Report Data for Patients Undergoing Cerebral Angiography.
    Diagnostics. 2021;11(1):14.
  3. Nagamoto K, Moritake T, Nakagami K, Morota K, Matsuzaki S, Nihei S, Kamochi M, Kunugita N.
    Occupational radiation dose to the lens of the eye of medical staff who assist in diagnostic CT scans.
    Heliyon. 2021;7(1):e06063.
  4. Matsuzaki S, Moritake T, Morota K, Nagamoto K, Nakagami K, Kuriyama T, Kunugita N.
    Development and assessment of an educational application for the proper use of ceiling-suspended radiation shielding screens in angiography rooms using augmented reality technology.
    European Journal of Radiology. 2021;143:109925.
  5. Nakagami K, Moritake T, Nagamoto K, Morota K, Matsuzaki S, Kuriyama T, Kunugita N.
    Strategy to Reduce the Collective Equivalent Dose for the Lens of the Physician’s Eye Using Short Radiation Protection Curtains to Prevent Cataracts.
    Diagnostics. 2021;11(8):1415.
  6. Nagamoto K, Moritake T, Nakagami K, Morota K, Matsuzaki S, Kunugita N.
    A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan.
    Journal of Occupational Health. 2021;63(1):e12305.
  7. Kowatari M, Nagamoto K, Nakagami K, Tanimura Y, Moritake T, Kunugita N.
    Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff.
    Journal of Radiation Protection and Research. 2022;47(1):39–49.
  8. Kowatari M, Nagamoto K, Nakagami K, Yoshitomi H, Moritake T, Kunugita N.
    Dose Measurement Precision of an RPLD-Based Eye Lens Dosemeter Applicable to the Medical Sector.
    Radiation Protection Dosimetry. 2022;198(17):1303–1312.
  9. Nagamoto K, Watanabe R, Kawachino T, Ohishi Y, Yamamoto A, Moritake T, Nihei S, Kamochi M, Kunugita N.
    Contribution of Organ-Based Tube Current Modulation to the Reduction of Lens Exposure Dose in Head 4D CT Imaging: A Phantom Study.
    Radiation Protection Dosimetry. 2022;198(18):1377–1386.
  10. Nagamoto K, Kunugita N.
    Effectiveness of a radiation management safety checklist for non-vascular imaging and interventional radiology at a medical facility.
    Environmental and Occupational Health Practice. 2022;5(1).
  11. Matsuzaki S, Moritake T, Sun L, Morota K, Nagamoto K, Nakagami K, Kuriyama T, Hitomi G, Kajiki S, Kunugita N.
    The Effect of Pre-Operative Verbal Confirmation for Interventional Radiology Physicians on Their Use of Personal Dosimeters and Personal Protective Equipment.
    International Journal of Environmental Research and Public Health. 2022;19(24):16825.
  12. Kowatari M, Yoshitomi H, Nagamoto K, Nakagami K, Moritake T, Kunugita N.
    Characterisation of small radiophotoluminescence dosemeter in terms of Hp(0.07) for extremity dose monitoring of medical personnel.
    Radiation Protection Dosimetry. 2023;199(15–16):1807–1812.
  13. Nagamoto K, Moritake T, Kowatari M, Nakagami K, Morota K, Matsuzaki S, Nihei S, Kamochi M, Kunugita N.
    Occupational radiation dose on the hand of assisting medical staff in diagnostic CT scans.
    Radiation Protection Dosimetry. 2023;199(15–16):1774–1778.
  14. Nagamoto K, Kawachino T, Suetsugu Y, Saruwatari H, Nihei SI, Kunugita N.
    Eye lens dose in spine surgeons during myelography procedures: a dosimetry study.
    Journal of Radiological Protection. 2023;43(4).
  15. Nagamoto K, Yoshizuka N, Kawano S, Nihei SI.
    Optimizing Radiation Protection in PET/CT Examinations: Reducing Occupational Exposure During Patient Positioning.
    Cureus. 2024;16(12):e75052.
  16. Nagamoto K, Kawachino T, Suetsugu Y, Urasaki R, Tokumoto S, Kohzaki M, Nihei S, Okazaki R.
    Evaluation of occupational radiation exposure and influencing factors for healthcare workers during diagnostic computed tomography imaging.
    Radiation Protection Dosimetry. 2025;201(7):522–531.
  17. Nagamoto K, Yamamoto A, Takahashi N, Nii A, Kohzaki M, Okazaki R.
    Occupational radiation exposure of zoo veterinarians during X-ray procedures: a real-time dosimetry study.
    Journal of Occupational Health. 2025;67:uiaf064.
  18. 永元啓介, 髙橋能理子, 山本愛菜, 徳本彩妃, 二井綾子, 香崎正宙, 岡﨑龍史.
    動物園・水族館における獣医療従事者の眼の水晶体および手指被ばく線量評価と防護対策の検証.
    日本野生動物医学会誌. 2026;31(2). 掲載予定.
  19. Nagamoto K, Suetsugu Y, Yamamoto A, Kohzaki M, Okazaki R.
    Evaluation of a Real-Time Dose Display System as a Behavioral Intervention to Improve Radiation Protection in Fluoroscopy: A Pilot Study.
    Radiation Protection Dosimetry. 2026.

Selected Conference Presentations

  • Nagamoto K, Moritake T, Morota K, Nakagami K, Matsuzaki S, Nihei S, Kamochi S, Kunugita N.
    Occupational radiation dose to the hand of medical staff who assist in diagnostic computed tomography.
    IM2022 / NEUDOS-14, Kraków, Poland, 2022.
  • 永元啓介, 川内野友則, 末次善紀, 徳本彩妃, 香崎正宙, 二瓶俊一, 岡﨑龍史.
    診断CT検査時の患者介助における医療従事者の手指線量低減への取り組み.
    第97回日本産業衛生学会, 2024.
  • 永元啓介, 髙橋能理子, 山本愛菜, 二井綾子, 徳本彩妃, 香崎正宙, 梅﨑淳一, 岡﨑龍史.
    用手保定法における獣医師の眼の水晶体被ばく低減に関する研究:放射線防護眼鏡の遮蔽効果.
    第30回日本野生動物医学会大会, 2024.
  • 永元啓介, 髙橋能理子, 山本愛菜, 二井綾子, 徳本彩妃, 香崎正宙, 梅﨑淳一, 岡﨑龍史.
    動物園・水族館における放射線管理と防護意識に関する全国アンケート調査.
    第98回日本産業衛生学会, 2025.
  • Nagamoto K, Yamamoto A, Kawachino T, Ohishi Y, Nihei S, Kohzaki M, Okazaki R.
    Occupational Hand Dose in Healthcare Personnel Assisting Patients during Diagnostic CT Procedures.
    32nd Korea-Japan-China Conference on Occupational Health and Safety, Seoul, Korea, 2025.
  • 永元啓介, 山本愛菜, 三河内梨帆, 髙橋能理子, 二井綾子, 宮嶋海, 香崎正宙, 岡﨑龍史.
    動物園におけるX線検査時の職業被ばくの測定とその可視化:リアルタイム線量計を用いた試行報告.
    第31回日本野生動物医学会大会, 2025.

Research Grants & Projects

Principal Investigator

  • 科学研究費補助金 若手研究 24K20187
    CT撮影における複合現実(MR)技術を活用した放射線防護教育プログラムの開発と評価
    2024–2026年度
  • 令和6年度 産業医学・産業保健重点研究助成
    獣医療従事者の放射線管理状況と職業放射線被ばく線量の実態調査
    2024年度
  • 2024年度 放射線災害・医科学研究拠点共同研究
    整形外科医師の手指被曝低減に向けた放射線防護手袋の効果評価
  • 令和7年度 産業医学・産業保健重点研究助成
    獣医療従事者の放射線管理状況と職業放射線被ばく線量の実態調査
    2025年度
  • 北九州産業学術推進機構 FAIS シーズ創出・実用性検証事業
    MR(Mixed Reality)技術を用いた獣医療従事者向け放射線防護教育支援システムの実用化
    2025年度
  • 大久保利晃産業保健奨励賞
    放射線防護教育の可視化と産業横断的展開―医療・獣医領域における実証と教育支援モデル構築―
    2025年度
  • 2026年度 放射線災害・医科学研究拠点共同研究
    整形外科医師の手指被曝低減に向けた放射線防護手袋の効果評価

Co-Investigator / Research Collaborator

科研費、労災疾病臨床研究事業、環境省研究事業等に研究分担者・研究協力者として参画しています。

Patent

線量計ホルダ
特許第7120569号
発明者:永元啓介、盛武敬、孫略、小野洋彰

トップへ戻る